Klik hier om terug te gaan. Pour vous assurer d'avoir accès aux informations produits les plus précises, nous vous avons redirigé vers la version anglaise de notre site web.
Cliquez ici pour revenir. Per garantirti l'accesso alle informazioni sui prodotti più accurate, ti abbiamo reindirizzato alla versione inglese del nostro sito web.
Clicca qui per tornare indietro.





Anaconda Sealtite ZHUA Black
Type ZHUA features a galvanised steelGalvanised steel is a zinc coated metal that provides customers with better resistance to corrosive environments. More core with a thick, smooth TPU cover which is Halogen freeHalogen-free cables, wires and conduits are applicable in delicate areas as, for example, public buildings and institutions or railway vehicles and in areas where the general safety requirements for cables and conduits are very high. More and flame retardant in line with the smoke and fire requirements of EN 45545-2 and NFPA 130, ASTM E162, E662 and BSS 7239 standards. The conduitA conduit is a gateway in which electrical wires or other items can pass through. More retains its flexibility at low and high temperatures and changing levels of humidity. Type ZHUA conduit is UL & CSA approved and has an integrated grounding copper wire (in sizes 1/2” to1.1/4”) to protect cables from electromagnetic interference. Type ZHUA is used in the metro-, train- and bus-building industry, in closed areas, airports, tunnels and (subway) stations, shipbuilding industry and navy.
- Agréments spéciauxSpecial approvals: UL-360 (file # E18917) and CSA C 22.2 (file LL15275 / 1117768). Applicable for NEC Article 250.118 (6), 350, 300.22 (D), 620.21 and 645.5 (E) (2). Suitable for use in hazardous environments according tot NEC: - Article 501.10 (B) (2) Class I, Division 2. - Article 502.10 (A) (2) and (B) (2) Class II, Division 1 and 2. - Article 503.10 (A) (3) and (B) Class III, Division 1 and 2. - EN 45545-2: R22 (interior equipment) class HL1 and HL2, R23 (exterior equipment) class HL1, HL2 and HL3. (Average results: CITnlp = 0,17, Dsmax < 300 and LOI > 32). - EN ISOThe International Organization for Standardization is a worldwide federation of national standards bodies. More 11925-2: passes the Allumability test at 30 sec. Flame property tests: Official tests (VTEC Laboratories Inc.) indicate that the Poly-Urethane used in ZHUA meets the requirements for NFPA 130, ASTM E162, ASTM E662 and BSS 7239.
- ConstructionHot dipped galvanised steel core, square locked with integral copper grounding wire till 1.1/4”, thick smooth Thermoplastic Polyurethane (V0-rated TPU compound) cover.
- Température-50 °C till +105 °C
- CouleurBlack
- Résistance à l'écrasement4 (1250N)
- Résistance aux chocs4 (6J)
- Résistance à la traction4 (1000N)
- Indice de protectionIP 66/67
- CoverTPU
| Size | Diameter | Bending radius | Standard carton | Small carton | Reels | Weight | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Inside | Outside | Static | Dynamic | Metre | Article No | Metre | Article No | Metre | Article No | (Kg/m) | |
| (mm) | (mm) | (mm) | (mm) | ||||||||
| 3/8" | 12,6 | 17,8 | 70 | 85 | 30 | 334.012.1 | - | - | 150 | 334.012.5 | 0,4 |
| 1/2" | 16,1 | 21,1 | 90 | 110 | 30 | 334.016.1 | - | - | 150 | 334.016.5 | 0,45 |
| 3/4" | 21,1 | 26,4 | 115 | 140 | 30 | 334.020.1 | - | - | 150 | 334.020.5 | 0,65 |
| 1" | 26,8 | 33,1 | 145 | 170 | 30 | 334.026.1 | - | - | 120 | 334.026.5 | 1,05 |
| 1.1/4" | 35,4 | 41,8 | 175 | 215 | 15 | 334.035.1 | - | - | 60 | 334.035.5 | 1,2 |
| 1.1/2" | 40,3 | 47,8 | 205 | 250 | 15 | 334.040.1 | - | - | 45 | 334.040.5 | 1,5 |
| 2" | 51,6 | 59,9 | 240 | 300 | 15 | 334.050.1 | - | - | 30 | 334.050.5 | 2,3 |
Anamet Europe B.V.
Galwin 5
NL-1046 AW Amsterdam
The Netherlands
-
+31 (0)20 586 35 86
-
sales@anamet.nl
-
Fax.: +31 (0)20 - 688 11 26
Marchés & Produits
Tenez-vous informé





























































